MPT50 Thread Mount Transducer Standard Range psi | Pressure and Temperature

MPT50 Thread Mount Transducer | 300, 500, 1k, 2k, 3k, 5k, psi | Pressure + Temperature

Micron's Model MPT50 is a threaded mount, miniature, low cost, general use pressure/temperature transducer. This transducer is made of corrosive resistant titanium (6AL4V). It utilizes high reliability bulk type semiconductor strain gages and temperature sensors bonded directly to the inside surface of the machined diaphragm.

Pressure on the diaphragm is applied through the hole in the 10-32 threaded nose which is then converted to an electric signal proportional to the pressure.

Titanium hermetic headers permit offering the MPT50 with absolute or seal reference options. The hermetic header is located just behind the strain gage diaphragm section of the sensor. Sealing the sensitive gages to an inert environment dramatically increases stability and reliability
Long term stability versions are available.

PERFORMANCE (PRESSURE) OPTIONS (ALL VALUES MAXIMUM) 
  Specification Options

A B C D Units
Balance (Zero) ±3.00 ±2.00 ±2.00 ±2.00 mV
Full Scale Sensitivity 20.0±2.00 20.0±2.00 20.0±2.00 20.0±2.00 mV/V
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS *BFSL
Thermal Balance (Zero) Shift ±0.02 ±0.02 ±0.01 0.005 %FS/°F
Thermal Sensitivity Shift ±0.02 ±0.02 ±0.01 ±0.005 %FS/°F
*BFSL=Best Fit Straight Line
 
PERFORMANCE (TEMPERATURE) 
Balance @ 0°C (32°F) ± 2.00 mV
Sensitivity (5.0 VDC excitation) 4.8 ± 0.5 mV/°F
Static Error Band ±0.5 °F*BFSL
Input Resistance 12K ± 1K Ohms
Output Resistance 11K ± 1K Ohms
 
MECHANICAL
Standard Pressure Ranges 300, 500, 1K, 2K, 3K, 5K psi
Non Standard Pressure Ranges 50, 100, 150, 200, 150, 10K psi
Other ranges possible Consult Factory
Over Pressure (No change in specifications) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
 
ENVIRONMENTAL
Storage and Operating Temperature 0° to 180°F
Compensated Temperature Range 30° to 130°F
Other Temperature Compensated Ranges Consult Factory
Acceleration (Consult factory for high vibration options) 100g's any axis 
Media Compatibility (wetted surface) Liquids & Gases compatible with Titanium 6AL4V
 
ELECTRICAL
Input 5.0 Volts DC or AC
Maximum Voltage 30 V for short periods
Input Resistance (Nominal) 1400 ± 400 Ohms
Output Resistance (Nominal) 850 ± 200 Ohms
Insulation Resistance Minimum 50 MOhms @ 50 VDC

MPT50 Drawing

MPT50 Pressure + Temperature Transducer Product Library

  MPT50 Data Sheet

  MPT50 Drawing


Tip: Hover and Click on any of the icons below.

The options for the MPT50 are listed below along with descriptions and 1-4 unit pricing.
Quantity Discounts Available for 5+ units. Contact Sales.

PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)
 
Performance Specification Options
A
B
C
D
Units
Balance (Zero)
±3.00
±2.00
±2.00
±2.00
mV
Full Scale Sensitivity
20.0±2.00
20.0±2.00
20.0±2.00
20.0±2.00
mV/V
Static Error Band
±0.50
±0.25
±0.25
±0.25
%FS*BFSL
Thermal Balance (Zero) Shift
±0.02
±0.02
±0.01
±0.005
%FS/°F
Thermal Sensitivity Shift
±0.02
±0.02
±0.01
±0.005
%FS/°F
 
*BFSL=Best Fit Straight Line
 
Standard Long Term Stability± 2.00 %FS/Year Max.
 
Long Term Stability Options
L10 = <1.0
L5= <0.5
L2= <0.2
L1= <0.1
%FS/°F
 
PERFORMANCE (TEMPERATURE) 
Balance @ 0°C (32°F) ± 2.00 mV
Sensitivity (5.0 VDC excitation) 4.8 ± 0.5 mV/°F
Static Error Band ±0.5 °F *BFSL
Input Resistance 12K ± 1K Ohms
Output Resistance 11K ± 1K Ohms
MECHANICAL
Standard Pressure Ranges 300, 500, 1K, 2K, 3K, 5K, psi
Non Standard Pressure Ranges 15, 20, 25, 30, 35, 40, ,50 100, 150, 200, 250, 10K psi
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
Titanium hermetic headers permit Absolute or Sealed Reference options. The header is located just behind the strain gage diaphragm of the sensor. Sealing the sensitive gages to an inert environment dramatically increases stability and reliability.
PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)
 
Performance Specification Options
A
B
C
D
Units
Balance (Zero)
±3.00
±2.00
±2.00
±2.00
mV
Full Scale Sensitivity
20.0±2.00
20.0±2.00
20.0±2.00
20.0±2.00
mV/V
Static Error Band
±0.50
±0.25
±0.25
±0.25
%FS*BFSL
Thermal Balance (Zero) Shift
±0.02
±0.02
±0.01
±0.005
%FS/°F
Thermal Sensitivity Shift
±0.02
±0.02
±0.01
±0.005
%FS/°F
 
*BFSL=Best Fit Straight Line
 
Standard Long Term Stability± 2.00 %FS/Year Max.
 
Long Term Stability Options
L10 = <1.0
L5= <0.5
L2= <0.2
L1= <0.1
%FS/°F
Standard Length on our Transducers is Three Feet. Additional cable can be purchased in several pre-determined lengths.