MP562  4-20mA Pressure Transducer

MP562 Pressure Transducer | 4-20 mA | 50-500, 1k, 2k, 3k, 5k, 7k

Micron’s Model MP562 is a miniature low cost, general use transducer. These transducers are made of corrosive resistant Titanium (6AL4V). They utilize high reliability bulk type semiconductor strain gages bonded directly to the inside surface of the machined diaphragm. Pressure on the diaphragm is applied through the hole in the nose which is then converted to an electric signal proportional to the pressure.
Model MP562 Constant Current 4~20mA

The Options for the MP562 are listed below along with descriptions and 1-4 unit pricing for each.

Quantity Discounts Available for 5+ units. Contact Sales

PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)

Specifications Options

A

B

C

D

Units

Balance (Zero) MP56

±3.00

±2.00

±2.00

±2.00

mV

Balance (Zero) MP562

4.00±0.50

4.00±0.30

4.00±0.20

4.00±0.20

mA

Full Scale Sensitivity MP56

20.0±2.00

20.0±2.00

20.0±2.00

20.0±2.00

mV/V

Full Scale Sensitivity MP562

20.0±0.50

20.0±0.30

20.0±0.20

20.0±0.20

mA

Static Error Band

±0.50

±0.25

±0.25

±0.25

%FS *BFSL

Thermal Balance (Zero) Shift

±0.02

±0.02

±0.01

±0.005

%FS/°F

Thermal Sensitivity Shift

±0.02

±0.02

±0.01

±0.005

%FS/°F

Long Term Stability (less than)

±2.00

±2.00

±2.00

±2.00

%FS/year

MECHANICAL

Standard Pressure Ranges

50, 100, 200, 300, 500, 1k, 2k, 3k, 5k, 7k psi Gage

Other ranges possible

10, 15, 25 psi Gage.

Over Pressure (No change out of spec.)

2.0x Range

Burst Pressure

6.0x Range

Liquids

Compatible with Titanium, 6AL4V.

ENVIRONMENTAL

Storage and Operating Temperature

0° - 180°F

Compensated Temperature Range

30° - 130°F

MP56 ELECTRICAL PERFORMANCE mV OUTPUT

Excitation

5 Volts Dc. or 10 Volts Dc.

Maximum Voltage

50 V for Short Periods

Input Resistance (Nominal)

1400 ± 400 ohms

Output Resistance (Nominal)

850 ± 200 ohms

Insulation Resistance Minimum

50 M ohms @ 50VDC

MP562 ELECTRICAL PERFORMANCE 4-20 mA OUTPUT

Excitation

12 to 30 VDC

Load Resistance

500 ohms - standard, see chart

Maximum Input Voltage

32 V for short periods

Insulation Resistance Minimum

50 M ohms @ 50VDC

MP56 Drawing

MP56 Drawing

MP562 Pressure Transducer Product Library

  MP562 Data Sheet

  MP562 Drawing

PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)
  A B C D UNITS
Balance (Zero)MP56 ±3.00  ±2.00 ±2.00 ±2.00 mV
Balance (Zero)MP562 4.00±0.50 4.00±0.30 4.00±0.20 4.00±0.20 mA
Full Scale SensitivityMP56 20.0±2.00 20.0±2.00 20.0±2.00 20.0±2.00 mV/V
Full Scale SensitivityMP562 20.0±0.50 20.0±0.30 20.0±0.20 20.0±0.20 mA
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS*BFSL
Thermal Balance (Zero) Shift ±0.02 ±0.02 ±0.01 ±0.005 %FS/°F
Thermal Sensitivity Shift ±0.02 ±0.02 ±0.01 ±0.005 %FS/°F
Long Term Stability (less than) ±2.00 ±2.00 ±2.00 ±2.00 %FS/year

MECHANICAL

Standard Pressure Ranges

50, 100, 200, 300, 500, 1k, 2k, 3k, 5k, 7k psi Gage

Other ranges possible

10, 15, 25 psi Gage.

Over Pressure (No change out of spec.)

2.0x Range

Burst Pressure

6.0x Range

Liquids

Compatible with Titanium, 6AL4V.

ENVIRONMENTAL

Storage and Operating Temperature

0° - 180°F

Compensated Temperature Range

30° - 130°F

Standard Length on our Transducers is Six Feet. Additional cable can be purchased in several pre-determined lengths.
  • Performance Spec. A
  • 50 psi
  • Gage
  • 1/8 in. NPT Pipe
  • Standard Cable Length 6 Feet
$307.00
$307.00
Loading...