MP402 Flush Mount Transducer Standard Range psi

MP402 Flush Mount Transmitter | 200, 300, 500, 1k, 3k, 5k psi | 4-20mA

Micron's Model MP402 is a miniature, low cost, general use pressure sensor that automatically compensates for line resistance and power supply changes. This transducer is made of corrosive resistant titanium (6AL4V) and utilizes high reliability bulk type semiconductor strain gages bonded directly to the inside surface of the machined diaphragm. Absolute or sealed reference sensors are available as an option. The hermetic header is located just behind the strain gage diaphragm section of the sensor, sealing the sensitive gages to an inert environment which dramatically increases stability and reliability.

Consult the factory for special temperature or pressure ranges and high-vibration resistant options. Long term stability versions are available.

PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)

A B C D Units
Balance (Zero) 4.00±0.50 4.00±0.30 4.00±0.20 4.00±0.20 mA 
Full Scale Sensitivity 16.00±0.50 16.00±0.30 16.00±0.20 16.00±0.20 mA
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS *BFSL
Thermal Balance (Zero) Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Thermal Sensitivity Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Long Term Stability ±2.00 ±2.00 ±2.00 ±2.00 %FS/year
*BFSL=Best Fit Straight Line
MECHANICAL 
Standard Pressure Ranges 200, 300, 500, 1K, 2K, 3K, 5K, PSI
Non Standard Pressure Ranges 5, 10, 15, 20, 25, 30, 50, 100, 150 10k PSI
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
ENVIRONMENTAL
Storage and Operating Temperature 0° to 180°F
Compensated Temperature Range 30° to 130°F
Acceleration
(Consult factory for high vibration options)
100g's any axis
Media Compatibility (wetted surface) Liquids & Gases compatible with Titanium 6AL4V
Other Temperature Compensated Ranges Consult Factory
ELECTRICAL
Input Voltage (Standard) 24 VDC
Input Load Resistance (Standard) 500 Ohms
Maximum Input Voltage 30 V for short periods
Insulation Resistance Minimum 50 MOhms @ 50 VDC

MP40 Drawing

MP402 Pressure Transmitter Product Library

  MP402 Data Sheet

  MP402 Drawing

What are the Pressure Adaptors Used For?


Tip: Hover and Click on any of the icons below.

The options for the MP402 are listed below along with descriptions and 1-4 unit pricing.
Quantity Discounts Available for 5+ units. Contact Sales.

PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)

A B C D Units
Balance (Zero) 4.00±0.50 4.00±0.30 4.00±0.20 4.00±0.20 mA
Full Scale Sensitivity 16.00±0.50 16.00±0.30 16.00±0.20 16.00±0.20 mA
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS *BFSL
Thermal Balance (Zero) Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Thermal Sensitivity Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Long Term Stability ±2.00 ±2.00 ±2.00 ±2.00 %FS/year
MECHANICAL
Standard Pressure Ranges 200, 300, 500, 1K, 2K, 3K, 5K, PSI
Non Standard Pressure Ranges 5, 10, 15, 20, 25, 30, 50, 100, 150 10k PSI
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
MECHANICAL
Standard Pressure Ranges 200, 300, 500, 1K, 2K, 3K, 5K, PSI
Non Standard Pressure Ranges 5, 10, 15, 20, 25, 30, 50, 100, 150 10k PSI
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
Titanium hermetic headers permit Absolute or Sealed Reference options. The header is located just behind the strain gage diaphragm of the sensor. Sealing the sensitive gages to an inert environment dramatically increases stability and reliability.
PERFORMANCE OPTIONS (ALL VALUES MAXIMUM)

A B C D Units
Balance (Zero) 4.00±0.50 4.00±0.30 4.00±0.20 4.00±0.20 mA
Full Scale Sensitivity 16.00±0.50 16.00±0.30 16.00±0.20 16.00±0.20 mA
Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS *BFSL
Thermal Balance (Zero) Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Thermal Sensitivity Shift ±0.02 ±0.01 ±0.01 ±0.005 %FS/°F
Long Term Stability ±2.00 ±2.00 ±2.00 ±2.00 %FS/year
MECHANICAL
Standard Pressure Ranges 200, 300, 500, 1K, 2K, 3K, 5K, PSI
Non Standard Pressure Ranges 5, 10, 15, 20, 25, 30, 50, 100, 150 10k PSI
Other ranges possible Consult Factory
Over Pressure (No change out of spec.) 2.0x Range
Usable Pressure (Small change in balance) 3.0x Range
Burst Pressure 6.0x Range
Standard Length on our Transducers is Three Feet. Additional cable can be purchased in several pre-determined lengths.
Micron's Pressure Adaptors are designed for use with our Flush Mount Pressure Transducers. Machined from 17-4PH Stainless Steel for use in demanding applications they are available in Several Thread Options and Sizes.
 
Pipe Threads (NPT)
1/16 in.
1/8 in.
1/4 in. 
  BSP Threads
1/4 BSP Type B
3/8 BSP Type B
  Straight Threads
3/8 in.   x 24
7/16 in. x 20
1/2 in.   x 20
Flush Mount | Standard Flush Mount Transducer
Use our Straight 3/8 x 24 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our Straight 7/16 x 20 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our Straight 1/2 x 20 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our Pipe 1/16 x 27 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our Pipe 1/8 x 27 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our Pipe 1/4 x 18 Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our BSP 1/4 Parallel Threaded Adaptor to convert your Flush Mount to a Threaded Mount
Use our BSP 3/8 Parallel Threaded Adaptor to convert your Flush Mount to a Threaded Mount
  • Performance Spec. A
  • 200 psi
  • Gage
  • Standard Stability
  • Standard Cable Length 3 feet.
  • Flush Mount
$233.00
$233.00